구매규격서 및 규격적합조사표
품 명(Description) : Gas Chromatograph Triple Quadrupole Mass Spectrometer | |||||
구 매 규 격 서 [ COMMODITY DESCRIPTION ] | |||||
품목번호 Item No. | 관세분류번호 HSK No. | 정부물품분류번호 | 수량 Q'ty | 단위 Unit | 비고 |
1 | 9027-81-0000 | 41115404 | 1 | set | |
Ⅰ. End-user's Use and Feature 1. Quantitative and qualitative analysis of residual pesticides in agricultural products is performed. 2. The main components of the mixture are identified using the SIM/Scan and MRM methods. 3. This equipment is used for research and experimental purposes. | |||||
Ⅱ. Configurations of Goods 1. Triple quadrupole gas chromatograph mass spectrometer 1) GC mainframe 1 set (주장비) 2) MS mainframe 1 set (주장비) 3) Auto injection system 1 set (주장비) 2. Data processing system 1 set (부속장비) 3. Accessories 1 set (부속장비) | |||||
III. Performance and Specification 1. Triple quadrupole gas chromatograph mass spectrometer 1) GC mainframe (1) Oven temperature range: Ambient +4℃ ~ 450℃ or wider (1℃ increment setting) (2) Retention time repeatability : <0.0008min or less (3) Oven rampe rate : Max 120℃/min or more (4) Peak area repeatability : <1% or less (5) Injection pressure range: 0 ~ 1,035 kPa or wider (6) Mass flow rate setting range : 0 ~ 1,300mL/min or wider (7) Injection temperature range : Ambient to 450 ℃ or more (8) Oven cool down time : 4.5 min (450 ℃ to 50 ℃) or less
2) MS mainframe (1) Mass analyzer and detector ① Collision Cell : 0 to 60 eV or wider ② Mass range : m/z 10 to 1090 or wider ③ Mass resolution : 0.5Da or Less (Not Manual tune) ④ Mass axis stability : ±0.1 u/48 hours or less ⑤ Scan Rate : 20,000 u/second (Q3 Scan) or more ⑥ Minimum event time : 3 msec or less ⑦ Maximum transitions : 16 transitions/event or more ⑧ Maximum events : 2048 events or more ⑨ Minimum Dwell Time : < 0.5 msec or less ⑩ Maximum MRM Speed : 500 or more MRM transitions/second ⑪ Dynamic range : 8 x 106 or more ⑫ EI Scan Sensitivity : 1 pg OFN (m/z 272) S/N ≥ 2,000:1 or more ⑬ EI MRM Sensitivity : 100 fg OFN (m/z 272→241) S/N ≥ 40,000:1 or more (2) Ion Source ① Ionization mode : EI ② Filament : Dual, automatic switching ③ Temperature : 140 to 300 ℃ or wider ④ Electron Energy : 10 to 200 eV or wider (3) Vacuum System ① Main Pump : Dual inlet turbo molecular pump 179 L/second + 185 L/second (He) or more ② Fore Pump : Oil rotary pump, 30 L/minute (60 Hz) or more 3) Auto Injection system (1) Sample injection volume : 0.1 ~ 8.0uL or wider (using 10uL syringe) (2) Number of samples : 1.5ml sample vials 100 vials or more (3) Number of sample injections : 1~99 or wider injections per sample (4) injection volume linearity : ±0.5% or less 2. Data processing system 1) MS measurement mode : Q1 scan, Q3 scan, Product ion scan, Precursor ion scan, Neutral loss scan, Q1 SIM, Q3 SIM, MRM and simultaneous analysis of Scan/SIM and Scan/MRM 2) Software control : GC, MS, Autosampler 3) Audit trail Support
3. Accessories 1) Rotary pump 1 set 2) Carrier Gas Supply Pipe 10m 2 ea 3) Tool kit 1 kit 4) Maintenance Kit 1 kit 5) Auto Sampler installation kit 1 kit 6) GAS FILTER,FOR HE KIT 1 kit 7) EXHAUST DUCT 1 set 8) Oil mist filter 1 set 9) Box, Heat processed (EI) 1 set 10) Repeller Assy, 1 set 11) GCMS Entry Kit 1 set Consist per 1 kit - Microliter syringe 10uL 1 ea - Premium Green Septa (50ea/set) 1set - graphite vespel ferrule 0.4 (10ea/set) 1set - graphite vespel ferrule 0.5 (10ea/set) 1set - O-ring for insert (10ea/set) 1set - deactivated insert with wool for split(5ea/set) 1set - deactivated insert with wool for splitless(5ea/set) 1set - Stainless steel nut (5ea/set) 1set 12) 5ms Column (0.25mmx0.25umx30m) 2 ea 13) 2mL Vial set with cap (100ea/set) 3 set 14) 4mL Vial set with cap (100ea/set) 1 set 15) GCMS Utility Supply system 1 set Consist - Carrier Gas Supply system - MS Table - Arm Hood System - UPS 5kW with Electricity distribution work - Rotary Pump Case 16) Power Cable, CE (KOR) 1 ea 17) Power CORD SET 1 ea 18) Data Processing Unit(PC) 1 set - CPU : Intel i7 processor or more - RAM : 16GB - HDD : 256GB SSD + 1TB HDD - ODD : DVD Multi - OS : Window 10 64bit Pro. ENG - Laser Printer - MS Office - Monitor : 24' LED Dual Monitor | |||||
Ⅳ. Compulsory Licenses and Qulifications required by relevant laws or regulations | |||||
Ⅴ. Remarks 1. The installation and operation should be carried out by contractor responsibility at user's site. 2. Two years warranty service should be provided by contractor after the installation. |